Order allow,deny Deny from all Vacutainers – One LabLink Store https://store.onelablink.com the first and largest medical supplies market place in Egypt Tue, 28 Mar 2023 10:05:12 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.2 https://store.onelablink.com/wp-content/uploads/2020/11/cropped-o-32x32.png Vacutainers – One LabLink Store https://store.onelablink.com 32 32 ESR Vacutainer https://store.onelablink.com/product/esr-vacutainer-copy/?utm_source=rss&utm_medium=rss&utm_campaign=esr-vacutainer-copy Thu, 26 May 2022 12:18:02 +0000 https://store.onelablink.com/?post_type=product&p=22568  

Vacutainer ESR Tubes chinese/ انابيب فاكيوتنر سرعة ترسيب صيني | Lab Supply

Blood Laboratory Erythrocyte sedimentation rate (ESR)
The ESR is a simple non-specific screening test that indirectly measures the presence of inflammation in the body. It reflects the tendency of red blood cells to settle more rapidly in the face of some disease states, usually because of increases in plasma fibrinogen, immunoglobulins, and other acute-phase reaction proteins. Changes in red cell shape or numbers may also affect the ESR.
Method
When anticoagulated whole blood is allowed to stand in a narrow vertical tube for a period of time, the RBCs – under the influence of gravity – settle out from the plasma. The rate at which they settle is measured as the number of millimeters of clear plasma present at the top of the column after one hour (mm/hr).
The Wintrobe sedimentation rackThere are two main methods used to measure the ESR: the Westergren method and the Wintrobe Method. Each method produces slightly different results. Most laboratories use the Westergren method.
Westergren method:
The Westergren method requires collecting 2 ml of venous blood into a tube containing 0 .5 ml of sodium citrate. It should be stored no longer than 2 hours at room temperature or 6 hours at 4 °C. The blood is drawn into a Westergren-Katz tube to the 200 mm mark. The tube is placed in a rack in a strictly vertical position for 1 hour at room temperature, at which time the distance from the lowest point of the surface meniscus to the upper limit of the red cell sediment is measured. The distance of fall of erythrocytes, expressed as millimeters in 1 hour, is the ESR.
Wintrobe method:
The Wintrobe method is performed similarly except that the Wintrobe tube is smaller in diameter than the Westergren tube and only 100 mm long. EDTA anticoagulated blood without extra diluent is drawn into the tube, and the rate of fall of red blood cells is measured in millimeters after 1 hour.  The shorter column makes this method less sensitive than the Westergren method because the maximal possible abnormal value is lower. However, this method is more practical for demonstration purposes.
This picture shows a rack holding Wintrobe tubes, in which anticoagulated whole blood has just been added.
(Time: 0)
Red blood cells have settled, leaving plasma at the top of the tube. Reading: 18 mm/hour
(Time: one hour)
Average values in healthy men are: <15mm/hr; in healthy females, they are somewhat higher: <20mm. The values are slightly higher in old age, in both genders.
Theoretical considerationsThe RBCs sediment because their density is greater than that of plasma; this is particularly so, when there is an alteration in the distribution of charges on the surface of the RBC (which normally keeps them separate form each other) resulting in their coming together to form large aggregates known as rouleaux.
Rouleaux formation is determined largely by increased levels of plasma fibrinogen and globulins, and so the ESR reflects mainly changes in the plasma proteins that accompany acute and chronic infections, some tumors and degenerative diseases. In such situations, the ESR values are much greater than 20mm/hr. Note that the ESR denotes merely the presence of tissue damage or disease, but not its severity; it may be used to follow the progress of the diseased state, or monitor the effectiveness of treatment.
Some interferences which increase ESR:
  • increased level of fibrinogen, gamma globulins.
  • technical factors: tilted ESR tube, high room temperature.
Some interferences which decrease ESR:
  • abnormally shaped RBC (sickle cells, spherocytosis).
  • technical factors: short ESR tubes, low room temperature, delay in test performance (>2 hours), clotted blood sample, excess anticoagulant, bubbles in tube.
Chronic inflammatory disease (collagen and vascular diseases) increases ESR.
Polycythemia decreases ESR.
]]>
Serum Gel Tube https://store.onelablink.com/product/serum-gel-tube/?utm_source=rss&utm_medium=rss&utm_campaign=serum-gel-tube Mon, 14 Mar 2022 10:25:09 +0000 https://store.onelablink.com/?post_type=product&p=21576
What is the role of gel in Vacutainers?
Serum separator gel that is located at end of the tube plays the role of a stable chemical and physical barrier between serum and blood clot 
]]>
Fluoride Vacutainer https://store.onelablink.com/product/fluoride-vacutainer/?utm_source=rss&utm_medium=rss&utm_campaign=fluoride-vacutainer Mon, 14 Mar 2022 10:23:42 +0000 https://store.onelablink.com/?post_type=product&p=21572 Fluoride Vacutainer are used to collect samples for glucose determinations.

Specified with gray stoppers.

]]>
Plain Vacutainer https://store.onelablink.com/product/plain-vacutainer/?utm_source=rss&utm_medium=rss&utm_campaign=plain-vacutainer Mon, 14 Mar 2022 10:22:38 +0000 https://store.onelablink.com/?post_type=product&p=21569
  • Product Details
  • Red cap vacutainer plain blood collection tube

Blood Collection Plain Tube

Introduction of our Venous blood collection tube

No additive. This Blood collection tube is used for blood specimen collection and storage for biochemistry, immunology, element trace, various types of virus detection and so on for clinical test. Blood Collection Glass Plain Tube shall be put in 37°C water for 1 hour after blood collection. Light yellow serum shall be visible before centrifuge.

Material Spec(mm) Volume(ml) Label Shelf life(year) Package
Glass 13*75 1,2,3,4 Paper label 2 100/1800
Glass 13*100 5,6 Paper label 2 100/1200
Glass 16*100 7,8,9,10 Paper label 2 100/1200
PET 13*75 1,2,3,4 Paper label/UV Printing 1 100/1800
PET 13*100 5,6 Paper label/UV Printing 1 100/1800
PET 16*100 7,8,9,10 Paper label/UV Printing 1 100/1200
]]>
PT Vacutainer https://store.onelablink.com/product/pt-vacutainer/?utm_source=rss&utm_medium=rss&utm_campaign=pt-vacutainer Mon, 14 Mar 2022 10:21:31 +0000 https://store.onelablink.com/?post_type=product&p=21567

PT Tube

Introduction:
Sodium citrate 3.2% or 3.8% is dispensed for coagulation test. Blood and liquid additive ratio is 9:1. This tube could not be used as first tube to collection blood. Invert 5-6 times after blood collection.
PRODUCT DETAILS
Material Spec(mm) Volume(ml) Label Shelf life(year) Package
Glass 13*75 2-4 Paper label 2 100/1800
Glass 13*100 5 Paper label 2 100/1200
PET 13*75 2-4 Paper label/UV Printing 1 100/1800
PET 13*100 5 Paper label/UV Printing 1 100/1800
PET+PP 13*75 2、3 Paper label/UV Printing 1 100/1800
]]>
EDTA Vacutainer https://store.onelablink.com/product/edita-vacutainer/?utm_source=rss&utm_medium=rss&utm_campaign=edita-vacutainer Mon, 14 Mar 2022 10:19:43 +0000 https://store.onelablink.com/?post_type=product&p=21565
EDTA Tube is widely used in clinical hematology as well as various kinds of blood cell test instruments.

 

]]>
Lithium Heparin blood collection tube (Green Tube cap) https://store.onelablink.com/product/lithium-heparin-blood-collection-tube-green-tube-cap/?utm_source=rss&utm_medium=rss&utm_campaign=lithium-heparin-blood-collection-tube-green-tube-cap https://store.onelablink.com/product/lithium-heparin-blood-collection-tube-green-tube-cap/#respond Mon, 02 Nov 2020 06:05:29 +0000 https://onemedmart.com/products/import-placeholder-for-12053/
  • Price/100 tubes (Rack).
  • Lithium heparin, or Sodium heparin, is dispensed for hemorhelogy or emergency biochemistry.
  • For Sodium in test, use Lithium heparin tube.
  • Invert 8-10 times after blood collection.
  • ]]>
    Glass 13×75 Volume (ml) 2, 3 Paper label Shelf Life 2 Years

     

    PET
    13×75
    Volume (ml) 2, 3
    Paper label/UV Printing
    Shelf Life 1 Year
    ]]>